A sensor in which an
ion-selective electrode is covered with a coating containing an enzyme which causes the reaction of an organic
or inorganic substance (substrate) to produce a species to which the electrode responds.
Alternatively, the sensor could be covered with a layer of substrate which reacts
with the enzyme, co-factor or
inhibitor to be assayed.
Source:
PAC, 1994, 66, 2527
(Recommendations for nomenclature of ionselective electrodes (IUPAC Recommendations
1994))
on page 2535
Cite as:
IUPAC. Compendium of Chemical Terminology, 2nd ed. (the "Gold Book"). Compiled by
A. D. McNaught and A. Wilkinson. Blackwell Scientific Publications, Oxford (1997).
XML on-line corrected version: http://goldbook.iupac.org (2006-) created by M. Nic,
J. Jirat, B. Kosata; updates compiled by A. Jenkins. ISBN 0-9678550-9-8.
https://doi.org/10.1351/goldbook.